Company:
Verify ID:
Expiration date:
ION AG 450
99.998% reduction of waterborne bacteria after 24 hours in 500-liter tank
500 litter tanks were filled with General Test Water as described in NSF P231, Microbiological Water Purifiers and inoculated with R. terrigena per NSF P231 guidelines. The cultures were homogenized, and purification product was added to the tank. Efficacy assessment was made at the time interval claimed by drawing from the bottom of the tank. Samples were analyzed following APHA Standard Method 9215C: Standard Methods for the Examination of Water and Wastewater for R. terrigena. Testing was completed on three separate units.
UL Verification is an objective, science-based assessment that confirms the accuracy of marketing claims. Our independent assessment process scrutinizes the validity of specific advertising or promotional statements, giving you a way to separate verified fact from fiction.