Surface Cleaning Appliance


Company:

Tineco Intelligent Technology Co.,Ltd

Verify ID:

V784559

Expiration date:

March 10, 2023 - March 09, 2025

Verification Mark

Applicable To:

FW11******, where “******” denotes differences in color and channel of distribution, SW010100US

Marketing Claim Verified by UL Solutions

Sanitizes non- porous hard floors in Steam Mode with tap water 99.99% reduction

Verification Method

The following organisms were used during the assessment of this verification: Staphylococcus aureus (ATCC 6538) Escherichia coli (ATCC 2592) Klebsiella pneumoniae (ATCC 4352) The organisms were applied to the hard surface(s) claimed and a cleaning cycle was performed, per the manufacturer’s instructions as well as the guidelines provided by ASTM E1153-14, Standard Test Method for Efficacy of Sanitizers Recommended for Inanimate, Hard, Nonporous Non-Food Contact Surfaces. For each test run, the following calculations were made: Percent Reduction = (ACC – ATC)/ACC x 100 Log Reduction = log ACC – log ATC or alternatively log (ACC/ATC) Where: ACC = average Positive Control Sample organism count before cycle (cfu/mL) ATC = average Test Sample organism count after cycle (cfu/mL)

What is UL Verification?

UL Verification is an objective, science-based assessment that confirms the accuracy of marketing claims. Our independent assessment process scrutinizes the validity of specific advertising or promotional statements, giving you a way to separate verified fact from fiction.