Applicable To:
BQ-100K6-260-Z, BQ-100K7-260-Z, BQ-150K6-260-Z, BQ-150K7-260-Z, BQ-200K6-260-Z, BQ-200K7-260-Z, BQ-250K6-260-Z, BQ-250K7-260-Z, BQ-320K6-260-Z, BQ-320K7-260-Z
Applicable SKUs:
Where Suffix “-Z” can be “-V”, ”-A”, “-D”, “-P”, “-AD”, “-AP”, “-PD”, “-AA”, “-N”. “-V” represent the product only have 0/1-10V, PWM and Resister dimming function.
“-A” represent the product have 12V AUX Output and 0/1-10V, PWM and Resister dimming function.
“-D” represent the product have adjust output current and power via external switch function and 0/1-10V, PWM and Resister dimming function.
“-P” represent the product have optical control function and 0/1-10V, PWM and Resister dimming function
“-AD” represent the product have 12V Aux output, adjust output current and power via external switch function and 0/1-10V, PWM and Resister dimming function.
“-AP” represent the product have 12V Aux output, optical control function and 0/1-10V, PWM and Resister dimming function.
“-PD” represent the product have optical control function, adjust output current and power via external switch function and 0/1-10V, PWM and Resister dimming function.
“-AA” represent the product have 12V Aux output, optical control function, adjust output current and power via external switch function and 0/1-10V, PWM and Resister dimming function.
“-N” represent the product only have output do not have any other function.
* The driver output current may be pre-set at the factory to any current setting within the output current rating via 0-10V/1-10V/PWM/dimming or adjustable resistor. The label may be additionally marked with current set (Iout).
Marketing Claim Verified by UL Solutions
120-480 Vac
model withstands
temperature
cycling shock test
per IEC 62384 at
-10°C/+95°C
Verification Method
The LED driver is subjected to the temperature cycling shock test and the supply voltage switching test per IEC 62384: 2020-05, DC or AC supplied electronic control gear for LED modules – Performance requirements, Section 12 Endurance.
What is UL Verification?