Company:
Verify ID:
Expiration date:
* This information was provided by Superior Essex International LP and may contain additional information outside the scope of this Claim Verification.
PW6H-Hxx-yB (xx represents packaging and y represents jacket color)
SIB 10G
Cable performance characteristics have been evaluated as outlined below to determine that the product satisfies the requirements of Sustainable Intelligent Building (SIB) Test Program for Type CMP PowerWise 10G cable part number PW6H-Hxx-yB (xx is for different packaging and y is for different jacket color) At Ambient (21C) Conditions: Data Rate Transmission per Bit Error Rate Testing | Single Cable Distance (Meters) using Smart Bits Tester Performance 10BaseT 200 100BaseT 195 1GBaseT 155 10GBaseT 110 Data Rate Transmission per HDBaseT™ transmission | Single Cable Distance (Meters) per UL 4299, Outline of Investigation for Performance Power Over HDBaseT™ (PoH) Cables HDBaseT 120 At LP 0.5A High Temperature (62.6C) Worst Case Conditions: Data Rate Transmission per Bit Error Rate Testing | Single Cable Distance (Meters) using Smart Bits Tester Performance 10BaseT 200 100BaseT 190 1GBaseT 145 10GBaseT 105 Data Rate Transmission per HDBaseT™ transmission | Single Cable Distance (Meters) per UL 4299, Outline of Investigation for Performance Power Over HDBaseT™ (PoH) Cables HDBaseT 110 At ambient & temperature equating to 0.5A operating temperature conditions: 10 Gb transmission distance 100 meter bundle per Bit Error Rate Testing using Spirent TestCenter transmission at ambient and LP 0.5A conditions in a 6 around 1 Bundle configuration as described in ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components with all 6 disturbing cables also running fully Saturated 10Gb traffic simultaneously. 100 meter transmission at 10Gb, with 6 cables bundled around 1 cable, tested at temperature equating to 0.5A powering conditions (62.6C). Center disturbed cable performance verified with zero bit errors via Spirent TestCenter. Bundle configuration as described in ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components with 10Gb traffic on all 6 disturber cables. 4K, UHD, 30 fps (or 30 Hz), 4:4:4, 8 bit color or 4K, UHD, 60 fps (or 60 Hz), 4:2:0, 8 bit color video transmission for 100m per HDBaseT™ 4k output test in a 6 around 1 Bundle configuration as described in ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components with all 6 disturbing cables also running the same HDBaseT™ 4k output simultaneously. 100 meter video transmission at 4K, 4:4:4, 30fps, 8 bit color depth (16 million+ colors) or 100 meter video transmission of 4K, 60 fps 4:2:0 chroma subsampling using HDBaseT™ 4K output test with cables bundled per ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components with 6 disturbing cables running HDBaseT™ around the 1 cable under test. Maximum bundle size of 91 cables operating at 0.5A per conductor for a 15°C temperature rise at a 45°C ambient per TIA TSB-184A. HDBaseT™ transmission distance of between 80-100 meters per UL 4299using a modular plug terminated link (direct connect) configuration 0.5A operating temperature. Power over Ethernet (PoE) delivery distance is as indicated for the PoE Type per DC resistance measurements in ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, and, the power source and powered device specifications in IEEE 802.3bt: IEEE Standard for Ethernet Amendment 2: Physical Layer and Management Parameters for Power over Ethernet over 4 pairs: Type CMP PowerWise 10G: Type 1 (15W): 340 m @ Ambient (21C) & 298 m @ LP 0.5A operating temperature Type 2 (30W): 212 m @ Ambient (21C) & 186 m @ LP 0.5A operating temperature Type 3 (60W): 212 m @ Ambient (21C) & 186 m @ LP 0.5A operating temperature Type 4 (90W): 214 m @ Ambient (21C) & 187 m @ LP 0.5A operating temperature Jacket Temperature Rating at least 75°C per UL Standard for Safety for Communications Cables, UL 444 test data Installation Type Designation: Type CMP per UL Standard for Safety for Communications Cables, UL 444 test data 10 Gb transmission (single cable) passive transmission performance per ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, from 1 MHz up to a maximum stop frequency of 650 MHz Power efficiency at an ambient temperature of 45 °C is 87.7%. Power efficiency at an ambient temperature of 62.6 °C (worst case) is 86.8%. Applicable To: SIB PowerWise 10G Permanent Link Component Description – Superior Essex cable with Legrand connectivity as follows: Type CMP and CMR PowerWise 10G cable part number PW6H-Hxx-yB or PW6H-Hxx-yA (xx is for different packaging and y is for different jacket color) RJ45 Plug – Part No. FTPU6A-5pk One Connector Channel Component Description - Superior cable with Legrand connectivity as follows: Type CMP and CMR PowerWise 10G cable part number PW6H-Hxx-yB or PW6H-Hxx-yA (xx is for different packaging and y is for different jacket color) RJ45 Plug – Part No. FTPU6A-5pk RJ45 Jack – Part No. HDJ6A-xx (xx is for different color) Stranded Patch Cord – Part No. MC6Ayy-xx (yy is for length in FT, xx is for different color) Solid Patch Cord – Part No. SC6ATLLDB-xx (T is for cable type, LL is for length in FT, xx is for different color) Two Connector Channel Component Description - Superior cable with LeGrand connectivity as follows: Type CMP PowerWise 10G cable part number PW6H-Hxx-yB (xx is for different packaging and y is for different jacket color) RJ45 Jack – Part No. HDJ6A-xx (xx is for different color) Stranded Patch Cord – Part No. MC6Ayy-xx (yy is for length in FT, xx is for different color) Solid Patch Cord – Part No. SC6ATLLDB-xx (T is for cable type, LL is for length in FT, xx is for different color) Verification Method Permanent Link- Channel Bit Error Rate Transmission (BERT) performance characteristics have been evaluated as outlined below to determine that the product satisfies the requirements of the Sustainable Intelligent Type (SIB) Test program using the components described above. At Ambient (21C) Conditions: Data Rate Transmission per Bit Error Rate Testing using Smart Bits Tester: 1 Gbps 155m 10 Gbps 110m At LP 0.5A High Temperature (62.6C) Worst Case Conditions: Data Rate Transmission per Bit Error Rate Testing using Smart Bits Tester: 1 Gbps 145m 10 Gbps 105m One Connector Channel - Channel Bit Error Rate Transmission (BERT) performance characteristics have been evaluated as outlined below to determine that the product satisfies the requirements of the Sustainable Intelligent Type (SIB) Test program using the components described above. At Ambient (21C) Conditions: Data Rate Transmission per Bit Error Rate Testing using Smart Bits Tester: 1G Channel = 155m, Horizontal cable = 147m, Stranded Patch Cord = 8m, Solid Patch Cord = 8m 2.5G Channel = 155m, Horizontal cable = 147m, Stranded Patch Cord = 8m, Solid Patch Cord = 8m 5G Channel = 155m, Horizontal cable = 147m, Stranded Patch Cord = 8m, Solid Patch Cord = 8m 10G Channel = 107m (stranded)/108m (solid), Horizontal cable = 105m, Stranded Patch Cord = 2m, Solid Patch Cord = 3m At LP 0.5A High Temperature (62.6C) Worst Case Conditions: Data Rate Transmission per Bit Error Rate Testing using Smart Bits Tester: 1G Channel = 145m, Horizontal cable = 137m, Stranded Patch Cord = 8m, Solid Patch Cord = 8m 2.5G Channel = 145m, Horizontal cable = 137m, Stranded Patch Cord = 8m, Solid Patch Cord = 8m 5G Channel = 145m, Horizontal cable = 137m, Stranded Patch Cord = 8m, Solid Patch Cord = 8m 10G Channel = 110m, Horizontal cable = 105m, Solid Patch Cord = 5m 10G Channel = 108m, Horizontal cable = 105m, Stranded Patch Cord = 3m Two Connector Channel - Channel Bit Error Rate Transmission (BERT) performance characteristics have been evaluated as outlined below to determine that the product satisfies the requirements of the Sustainable Intelligent Type (SIB) Test program using the components described above. At Ambient (21C) Conditions: Data Rate Transmission per Bit Error Rate Testing using Smart Bits Tester: 1G Channel = 155m, Horizontal cable = 139m, Stranded Patch Cord = 16m (2x8), Solid Patch Cord = 16m (2x8) 2.5G Channel = 155m, Horizontal cable = 139m, Stranded Patch Cord = 16m (2x8), Solid Patch Cord = 16m (2x8) 5G Channel = 155m, Horizontal cable = 143m, Stranded Patch Cord = 12m (2x6) 5G Channel = 155m, Horizontal cable = 139m, Solid Patch Cord = 16m (2x8) 10G Channel = 107m, Horizontal cable = 95m, Stranded Patch Cord = 12m, Solid Patch Cord = 12m At LP 0.5A High Temperature (62.6C) Worst Case Conditions: Data Rate Transmission per Bit Error Rate Testing using Smart Bits Tester: 1G Channel = 145m, Horizontal cable = 129m, Stranded Patch Cord = 16m (2x8), Solid Patch Cord = 16m (2x8) 2.5G Channel = 145m, Horizontal cable = 129m, Stranded Patch Cord = 16m (2x8), Solid Patch Cord = 16m (2x8) 5G Channel = 145m, Horizontal cable = 133m, Stranded Patch Cord = 12m (2x6) 5G Channel = 145m, Horizontal cable = 129m, Solid Patch Cord = 16m (2x8) 10G Channel = 105m, Horizontal cable = 95m, Stranded Patch Cord = 10m, Solid Patch Cord = 10m
UL Verification is an objective, science-based assessment that confirms the accuracy of marketing claims. Our independent assessment process scrutinizes the validity of specific advertising or promotional statements, giving you a way to separate verified fact from fiction.