Anixter Utility Grade Infrastructure

Brand:
CommScope Technologies, LLC
Verify ID:
B239942
Effective Date:
May 21, 2019 - May 20, 2020
Verification Mark

Applicable To:
Commscope 2071E

Marketing Claim Verified by UL

Anixter Utility Grade Infrastructure UTG10

Verification Method

Cable performance characteristics have been evaluated as outlined below to determine that the product satisfies the requirements of UTG10. 10 Mb transmission distance up to at least 185 meters per Bit Error Rate Testing using Smart Bits Tester (single cable) 100 Mb transmission distance up to at least 150 meters per Bit Error Rate Testing using Smart Bits Tester (single cable) 1Gb transmission distance up to at least 100 meters per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) 1Gb transmission distance up to at least 100 meters at a temperature of at least 60°C per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) 10 Gb transmission distance between 37 - 50 meters per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) Transmission performance per ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, from 1 MHz up to a maximum stop frequency of 425 MHz. 1080p HD video surveillance transmission up to at least 150m per Transmission Distance test at 100 Mb and Type 2 PoE distance test. 4K UHD video surveillance transmission for at least 150m per Transmission Distance test at 100 Mb and Type 2 PoE distance test. Maximum bundle size of 72 -90 cables operating at 0.5A per conductor for a 15°C temperature rise at a 45°C ambient per TIA TSB-184A. HDBaseT™ transmission distance of between 80 – 100 meters per UL 4299, Outline of Investigation for Power Over HDBaseT™ (PoH) Cables, using a modular plug terminated link (direct connect) configuration at room ambient. Power over Ethernet (PoE) delivery distance is as indicated for the PoE Type per DC resistance measurements in ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, and, the power source and powered device specifications in IEEE 802.3bt: IEEE Standard for Ethernet Amendment 2: Physical Layer and Management Parameters for Power over Ethernet over 4 pairs: Type 1: 150 m Type 2: 150 m Type 3: 100 m Type 4: 100 m Jacket Temperature Rating at least 75°C per UL Standard for Safety for Communications Cables, UL 444 test data Installation Type Designation: CMR or CMP per UL Standard for Safety for Communications Cables, UL 444 test data A maximum flexing force as specified when tested with a force applied 1 inch from the point of cable exit from a securing fixture through an arc of 10 degrees: Flex Force 3: 46 – 60 oz-ft Flex Force 2: 31 – 45 oz-ft Flex Force 1: 16 – 30 oz-ft

What is UL Verification?

UL Verification is an objective, science-based assesment that confirms the accuracy of marketing claims. Our independent assesment process scrutinizes the validity of specific advertising or promotional statements, giving you a way to separate verified fact from fiction.