Wesco Utility Grade Infrastructure


Company:

CommScope Technologies, LLC

Verify ID:

B239942

Expiration date:

May 21, 2019 - May 21, 2024

Verification Mark

Applicable To:

CommScope 2071E, 1071E, 3071E-C

Marketing Claim Verified by UL Solutions

Wesco Utility Grade Infrastructure UTG10

Verification Method

Cable performance characteristics have been evaluated as outlined below to determine that the product satisfies the requirements of UTG10. 10 Mb transmission distance up to at least 185 meters per Bit Error Rate Testing using Smart Bits Tester (single cable) 100 Mb transmission distance up to at least 150 meters per Bit Error Rate Testing using Smart Bits Tester (single cable) 1Gb transmission distance up to at least 100 meters per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) 10 Gb transmission distance between 37-50 meters per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) Transmission performance per ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, from 1 MHz up to a maximum stop frequency of 450 MHz. Transmission performance per ISO/IEC 11801-1 Information technology – Generic cabling for customer premises – Part 1: General requirements, from 1 MHz up to a maximum stop frequency of 450 MHz. Transmission performance per EN 50173-1 Information technology – Generic cabling systems – Part 1: General requirements from 1 MHz up to a maximum stop frequency of 450 MHz. 1080p HD video surveillance transmission up to at least 150m per Transmission Distance test at 100 Mb and Type 2 PoE distance test. 4K UHD video surveillance transmission up to at least 150m per Transmission Distance test at 100 Mb and Type 2 PoE distance test. Maximum bundle size of 72 cables operating at 0.5A per conductor for a 15°C temperature rise at a 45°C ambient per TIA TSB-184-A. Maximum round bundle size of 72 cables operating at 0.5A per conductor for a 15°C temperature rise at a 45°C ambient in a ventilated environment, RP3 as defined in ISO/IEC 14763-2 and EN50174. HDBaseT™ transmission distance of between 80-100 meters per UL 4299, Outline of Investigation for Power Over HDBaseT™ (PoH) Cables, using a modular plug terminated link (direct connect) configuration at room ambient.   Power over Ethernet (PoE) delivery distance is up to at least as indicated for the PoE Type per DC resistance measurements in ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, ISO/IEC 11801-1 Information technology – Generic cabling for customer premises – Part 1: General requirements, EN 50173-1 Information technology – Generic cabling systems – Part 1: General requirements, and the power source and powered device specifications in IEEE 802.3bt: IEEE Standard for Ethernet Amendment 2: Physical Layer and Management Parameters for Power over Ethernet over 4 pairs: Type 1: 185 m Type 2: 150 m Type 3: 100 m Type 4: 100 m Jacket Temperature Rating at least 75°C per UL Standard for Safety for Communications Cables, UL 444 test data NEC Type Designations: Listed Type CMR or CMP per UL Standard for Safety for Communications Cables, UL 444 test data. The cables are CPR Classified in accordance with EN 50575 as follows: - 3071E-C: Cca, s1a, d1, a1 A maximum flexing force as specified when tested with a force applied 1 inch from the point of cable exit from a securing fixture through an arc of 10 degrees: FLEX FORCE 1: 46-65 oz-ft / 3.9-5.5 N·m FLEX FORCE 2: 31-45 oz-ft / 2.6-3.8 N·m FLEX FORCE 3: 15-30 oz-ft / 1.3-2.5 N·m Using the following Axis Network Cameras and a total channel length of up to 185 meters, which includes 170 meters of horizontal cable of cable and up to 15 meters of patch cords: M1134, -35 M3057-PLVE, -58-PLVE, -64-V, -65-V, -66-V, -75-V M3205-LVE, -06-LVE P1375, -E, -1377, -1378 P1445-LE, -1447-LE, -1448-LE P3227-LV, -LVE, 3228-LV, -LVE P3245-LV, -LVE, -V, -VE P3807-PVE P5654-E, -55-E Q1645, -47 Q1700-LE, -85-LE, -86-LE Q3515-LV, -LVE, -3517-LV, -LVE, -3518-LVE Q3527-LVE Q6074, -75 Q9216-SLV Using the following Axis Network Cameras and a total channel length of up to 175 meters, which includes 160 meters of horizontal cable of cable and up to 15 meters of patch cords: P3715-PLE, -17-PLE, -19-PLE For each channel length tested, there were zero dropped frames during camera operation for a period of one minute. 1Gb transmission distance using Spirent TestCenter/Copper Ethernet Test Module (single cable) and transceiver Prolabs part number UTG-SFP-1000BASE-T-C for a total channel length of up to 150 meters. Using the following audio devices at 100 Mb transmission and a total channel length of up to 185 meters, which includes 170 meters of horizontal cable and up to 15 meters of patch cords: C1310-E C1004-E (black) C1004-E (white) C2005 C1410 C8033 C8210 I8016-LVE A8207-VE MKII For each channel length tested, there were zero dropped frames during camera operation for a period of one minute.

About the Company

At CommScope we push the boundaries of communications technology to create the world’s most advanced networks. We design, manufacture, install and support the hardware infrastructure and software intelligence that enable our digital society to interact and thrive. Working with customers, we advance broadband, enterprise and wireless networks to power progress and create lasting connections. Across the globe, our people and solutions are redefining connectivity, solving today’s challenges and driving the innovation that will meet the needs of what’s next.

https://www.commscope.com/

What is UL Verification?

UL Verification is an objective, science-based assessment that confirms the accuracy of marketing claims. Our independent assessment process scrutinizes the validity of specific advertising or promotional statements, giving you a way to separate verified fact from fiction.