Company:
Verify ID:
Expiration date:
Panduit PUR6004, PUP6004, PUY6004 & PUC6004
Wesco Utility Grade Infrastructure UTG10
Cable performance characteristics have been evaluated as outlined below to determine that the product satisfies the requirements of UTG10. 10 Mb transmission distance up to at least 185 meters per Bit Error Rate Testing using Smart Bits Tester (single cable) 100 Mb transmission distance up to at least 150 meters per Bit Error Rate Testing using Smart Bits Tester (single cable) 1Gb transmission distance up to at least 100 meters per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) 1Gb transmission distance up to at least 100 meters at a temperature of at least 60°C per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) 10 Gb transmission distance between 37 - 50 meters per Bit Error Rate Testing using Spirent TestCenter / Copper Ethernet Test Module (single cable) Transmission performance per ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, from 1 MHz up to a maximum stop frequency of 425 MHz. 1080p HD video surveillance transmission up to at least 150m per Transmission Distance test at 100 Mb and Type 2 PoE distance test. 4K UHD video surveillance transmission for at least 150m per Transmission Distance test at 100 Mb and Type 2 PoE distance test. Maximum bundle size of 72 -90 cables operating at 0.5A per conductor for a 15°C temperature rise at a 45°C ambient per TIA TSB-184A. HDBaseT™ transmission distance of between 80 – 100 meters per UL 4299, Outline of Investigation for Power Over HDBaseT™ (PoH) Cables, using a modular plug terminated link (direct connect) configuration at room ambient. Power over Ethernet (PoE) delivery distance is as indicated for the PoE Type per DC resistance measurements in ANSI/TIA-568.2-D: Balanced Twisted-Pair Telecommunications Cabling and Components, and, the power source and powered device specifications in IEEE 802.3bt: IEEE Standard for Ethernet Amendment 2: Physical Layer and Management Parameters for Power over Ethernet over 4 pairs: Type 1: 185 m Type 2: 150 m Type 3: 100 m Type 4: 100 m Jacket Temperature Rating at least 75°C per UL Standard for Safety for Communications Cables, UL 444 test data Installation Type Designation: CMR or CMP per UL Standard for Safety for Communications Cables, UL 444 test data A maximum flexing force as specified when tested with a force applied 1 inch from the point of cable exit from a securing fixture through an arc of 10 degrees: FLEX FORCE 1: 46-65 oz-ft FLEX FORCE 2: 31-45 oz-ft FLEX FORCE 3: 15-30 oz-ft Using the following Axis Network Cameras and a total channel length of up to 185 meters, which includes 170 meters of horizontal cable of cable and up to 15 meters of patch cords: M1134, -35 M3057-PLVE, -58-PLVE, -64-V, -65-V, -66-V, -75-V M3205-LVE, -06-LVE P1375, -E, -1377, -1378 P1445-LE, -1447-LE, -1448-LE P3227-LV, -LVE, 3228-LV, -LVE P3245-LV, -LVE, -V, -VE P3807-PVE P5654-E, -55-E Q1645, -47 Q1700-LE, -85-LE, -86-LE Q3515-LV, -LVE, -3517-LV, -LVE, -3518-LVE Q3527-LVE Q6074, -75 Q9216-SLV Using the following Axis Network Cameras and a total channel length of up to 175 meters, which includes 160 meters of horizontal cable of cable and up to 15 meters of patch cords: P3715-PLE, -17-PLE, -19-PLE For each channel length tested, there were zero dropped frames during camera operation for a period of one minute.
UL Verification is an objective, science-based assessment that confirms the accuracy of marketing claims. Our independent assessment process scrutinizes the validity of specific advertising or promotional statements, giving you a way to separate verified fact from fiction.